There is no flow directions.
An arrow nameplate is attached to the edge of the flange on the primary side.
Set the valve so that the hole of the ball face to the primary side when the valve is closed.
Please click here for abnormal pressure rise.
An arrow nameplate is attached to the edge of the flange on the primary side.
Set the valve so that the hole of the ball face to the primary side when the valve is closed.
The seat of the V-port valve is installed on only one side.
Pipe so that the seat comes to the primary side when the valve is closed.
The body has an arrow for casting. Follow this.
There is no restriction on the flow direction.
In all positions, there is no restriction in the flow direction.
There is no restriction on the flow direction.